Skip to Content

ROCK PREMIUM



ROCK PREMIUM is a Plastomeric high performance, prefabricated, modified bitumen waterproofing membrane consisting of proprietary waterproofing bitumen compound, rein- forced with Non-Woven Polyester Carrier.

Description:

Rock Premium is a Plastomeric high performance, prefabricated, modified bitumen waterproofing membrane consisting of proprietary waterproofing bitumen compound, rein- forced with Non-Woven Polyester Carrier.

Rock Premium proprietary waterproofing com- pound is formulated with high grade bitumen modified with Atactic polypropylene (APP) to increase elasticity, flexibility, and enhanced with admixture of Thermoplastic materials to gain high heat resistance, good elongation and low temperature flexibility.

To improve the UV resistance and durability for The Product, the membrane is coated with Mineral Stabilizers.

Application:

Rock Premium waterproofing membrane are used for a wide variety of application:

  • Roofing or Re-roofing for covered single layer system or as a base layer for multi-layer systems.
  • Wet area, Swimming Pool and Toilets.
  • Underground waterproofing
  • Flat and Sloped roofing
  • The Product could be applied for waterproofing of foundations and engineering
  • structures by torching, hot air generator or by using special adhesives in both cold and hot applications.
  • Cleaning the substrate surface is a must, till it becomes dry, smooth, and remove any particles.
  • Based on surface conditions, a coat of ROCKAL primer product will be required prior to the application of the membrane.
  • According to the waterproofing system design and adhesion instruction, APP-Product can be applied to the substrate fully bonded, semi bonded or loose laid.
  • Overlapping is essential as follow, side laps from 8-10 cm and end laps from 12-15 cm.
  • Please refer to the ROCKAL applicator guide for complete instruction on the application of the product guide for complete instruction on the application of the product

Key Features:

  • High U.V. resistance (Mineral Finish).
  • Excellent thermal resistance. Strong adhesion to substrate.
  • Proven water impermeability.
  • Chemical resistance to wide range of light acidic, alkaline solutions and bacteria.

Reinforcement:

There are several types of reinforcement materials used in bituminous membranes, including:

  • Non- woven Glass fiber Reinforcement: provides tensile strength and dimensional stability

  • Non-woven polyester fabric: provides tensile strength and stability

  • Non-woven Polyester reinforcement reinforced with fiberglass filaments composite : Very high tensile strength, excellent elongation properties and good dimensional stability.
  • Compound Base: High tensile strength and good dimensional stability 

The choice of reinforcement material depends on the specific requirements of the roofing system and the desired properties such as reflectivity, dimensional stability, and resistance to environmental factors.

Surface Finish:

The surface finish of a bituminous membrane refers to the final appearance of the membrane once it has been installed on the roof. The surface finish can have an impact on the overall aesthetic of the roof, as well as its performance. Some common types of surface finishes for bituminous membranes include:

  • Sand finish: a rough, textured surface that helps to increase the coefficient of friction and improve slip resistance, Specially (White/Yellow)

  • Granulated finish: a surface that is covered with small, granulated particles, typically made of a durable material such as aluminum oxide. This finish provides a high level of slip resistance and UV stability. Available in colors (Red, Grey, Green)

  • Smooth finish: a smooth surface that provides a sleek, modern appearance, but may have lower slip resistance compared to other finishes.

The choice of surface finish depends on the specific requirements of the roofing system, such as the desired level of slip resistance and the type of roof deck.

Methods of Installation:

The installation methods for APP (Atactic Polypropylene) bituminous membrane vary depending on the specific requirements of the roofing system and the type of membrane being used. Some common methods of installation include:

  • Heat welded seam method: involves heating the overlapped edges of the membrane with a propane torch to create a seamless, watertight bond between the two pieces of membrane.

  • Self-adhesive method: involves removing the release paper from the self-adhesive backing on the membrane and pressing it onto the roof deck.

  • Torch-on method: involves heating the bituminous membrane with a torch and then pressing it onto the roof deck, where it will fuse and adhere to the surface.

  • Mechanically fastened method: involves using special mechanical fasteners to attach the membrane to the roof deck.

The choice of installation method will depend on factors such as the type of roof deck, the local building codes and regulations, and the desired level of seam strength and durability. It is recommended to seek the guidance of a professional roofing contractor for the installation of an APP bituminous membrane.

Rock Premium Membrane Characteristics:

TestTest MethodToleranceResultUnitالاختبار
ThicknessEN 1849-1±5%4mmالسمك
WidthEN 1848-1±1%1mالعرض
LengthEN 1848-1±1%10mالطول
StraightnessEN 1848-1-± 6mmدرجة اإلستقامة
Softening Point (R&B)ASTM D-36150°Cدرجة التطرية
Flexibility at low temperatureEN 1109 ASTM D-5147--12:- 15°Cالمرونة عند درجات الحرارة المنخفضة
Flow resistance at elevated temperature EN 1110 ASTM D-5147-10120°Cالثبات عند درجات الحرارة العالية
Tensile Strength-LongitudinalEN 12311-1ASTM D-5147± 25%1100N/5cmمقاومة الشد القصوي-طوليا
Tensile Strength-TransverseEN 12311-1ASTM D-5147± 25%750N/5cmمقاومة الشد القصوي-عرضيا
Elongation @Break -LongitudinalEN 12311-1ASTM D-5147± 1550%معدل اإلستطالة - طوليا
Elongation @Break -TransverseEN 12311-1ASTM D-5147± 1555%معدل اإلستطالة - عرضيا
Tearing Strength-LongitudinalEN 12310-1290Nمقاومة التمزق-طوليا
Tearing Strength-TransverseEN 12310-1300Nمقاومة التمزق-عرضيا
Tensile Tear Resistance-LongitudinalASTM D-5147 D-4073± 20%700Nمقاومة  التمزق بطريقة الشد-طوليا
Tensile Tear Resistance-TransverseASTM D-5147 D-4073± 20%500Nمقاومة التمزق بطريقة الشد-عرضيا
Resistance to Static LoadingEN 1273020Kgمقاومة اإلختراق اإلستاتيكى
Resistance to Impact LoadingEN 126911250mmمقاومة اإلختراق الديناميكى
Shear Resistance of joint L/TEN 12317-1± 20%900/600N/5cmمقاومة الشد عند منطقة التركيب (طوليا/عرضيا)
Dimensional Stability L/TEN 1107-1-1%ثبات األبعاد
Adhesion to concretePelage UEATC-20N/5cmقوة اإللتصاق باالسطح الخرسانية
Water absorptionASTM D-51470.15% درجة إمتصاص الماء
Fire Classification - Extemal Fire PerformanceEN 13501-5-F roof-تصنيف الحريق-أداء الحريق الخارجي
Reaction to fireEN 13501-1-E-رد الفعل عند التعرض للنار
Water Impermeability at Low PressureEN 1928 method A-Pass60Kpaعدم نفاذية الماء للضغط المنخفض
Water Impermeability at High PressureEN 1928 method B-Pass200Kpaعدم نفاذية الماء للضغط المرتفع
Thermal Ageing in air (in oven 4 weeks at 70 ± 2°C)EN 1296-Pass-اإلهتراء نتيجة التسخين
Ageing Due to Atmospheric Agents (U.V. Test weathering)ASTM G 53 UNI 8202/29-Pass-مقاومة التقادم لالشعة فوق البنفسجية
Average loss of slatesEN 1203930%متوسط الفاقد من الحبيبات

Note 

•  Products could vary in: Thickness - 3:4mm

•  ± All Tolerances according to UEAtc Directives

•  PES: Non-Woven Polyester Reinforcement Carrier

 

GET IN TOUCH 

  • Sales@Sealvergebyrockal.com

  • Asmaa Fahmy Street-Nasr City- Cairo- Egypt.

  • 01000223381

  • Contact us